ST=0, CYC2=0, CYC4=0, SY0=0, CYC5=0, CYC3=0, CYC1=0, CYC0=0
MINT Interrupt Source Status Register
ST | STCA Status Flag 0 (0): No change in the state of the STCA module 1 (1): A change in the state of the STCA module |
SY0 | SYNFP0 Status Flag 0 (0): No change in the state of the SYNFP0 module 1 (1): A change in the state of the SYNFP0 module |
CYC0 | Pulse Output Timer 0 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 0 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 0 is detected. |
CYC1 | Pulse Output Timer 1 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 1 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 1 is detected. |
CYC2 | Pulse Output Timer 2 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 2 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 2 is detected. |
CYC3 | Pulse Output Timer 3 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 3 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 3 is detected. |
CYC4 | Pulse Output Timer 4 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 4 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 4 is detected. |
CYC5 | Pulse Output Timer 5 Rising Edge Detection Flag 0 (0): A rising edge in the periodic pulse signal from pulse output timer 5 is not detected. 1 (1): A rising edge in the periodic pulse signal from pulse output timer 5 is detected. |